NASA-CR-2299

Pressure recovery performance of conical diffusers at high subsonic Mach numbers

Note:

This document has not been validated by ESDU. It is provided to our users as a useful reference source.

Abstract:

The pressure recovery performance of conical diffusers has been measured for a wide range of geometries and inlet flow conditions. The approximate level and location (in terms of diffuser geometry of optimum performance were determined. Throat Mach numbers from low subsonic (m sub t equals 0.2) through choking (m sub t equals 1.0) were investigated in combination with throat blockage from 0.03 to 0.12. For fixed Mach number, performance was measured over a fourfold range of inlet Reynolds number. Maps of pressure recovery are presented as a function of diffuser geometry for fixed sets of inlet conditions. The influence of inlet blockage, throat Mach number, and inlet Reynolds number is discussed.

Author(s):
F.X. Dolan; P.W. Runstadler Jr

Indexed under:

  • None

Details:

NASA-CR-2299
Format:
  • PDF (from scanned original)
Status:
  • Original, issued 01 Jan 1973
Previous Releases:
  • None available